Compu-Site Technologies and Smoke Guard have teamed up to provide innovative and aesthetically appealing fire and smoke protection systems to fit any purpose and any opening in your building. Whether it is smoke migration protection at the elevator hoist way or large opening protection for your atrium or stairway we have systems to cover any opening. For your next Healthcare, Hospitality, Education, or High Rise project be sure to contact Compu-Site for all of your smoke migration solutions!
Schedule a Smoke & Fire Curtain Lunch & Learn presentation!Smoke Guard M200 System - Designed to fit standard elevator openings, the M200 Smoke Guard System comes in two housing sizes and requires the provided full length auxiliary rails to create the magnetic seal from the housing to the floor. As Smoke Guards most affordable smoke migration solution this model comes in 42” or 48” widths with a max ceiling height of 12’ and a projection depth of 1” standard. For more information.
Smoke Guard M400 System - Flexibility and convenience are the hallmarks of the Smoke Guard system M400 design. This unit is available in custom screen sizes to fit elevator door openings up to 60” wide, has optional auxiliary rails, and features an automatic housing door reset. For more information.
Smoke Guard M600 System - The Smoke Guard M600 is the most customizable elevator smoke containment system on the market! With custom screen and housing sizes available to fit door openings up to 96” wide you will be sure to accommodate any project. These units also come standard with an automatic door closer and battery backup power. For more information.
Smoke Guard M1000 System - The M1000 system is designed to provide a 2 hour fire rated protection for windows. This system can be custom designed to protect window openings < 8’ wide by < 8’ tall and comply with UL 10B and UL 10C standard.
Smoke Guard M2100 System - This automatic Smoke/Fire Containment system is custom made to provide protection on openings up to 16’ wide and 12’ tall. The standard drive system features a gravity fail safe deployment without auxiliary power. With housing dimensions of 6.5” x 6.5” this unit can work in almost any application including being used as an automatic draft curtain. The M2100 features a battery backup UL 864 controller and is UL 10B, UL 10C, UL 10D and UL 1784 compliant.
Smoke Guard M2500 System - This Large Opening Smoke/Fire Containment system is custom made to provide protection on openings ≤ 60' wide by ≤ 12' tall; ≤ 50' wide x ≤ 16' tall; ≤ 40' wide x ≤ 20' tall. This system features a gravity fail safe deployment, battery backup, and can be manufactured with an optional egress flap and/or wall mounted egress buttons. The M2500 is UL 10B, UL 10C, UL 10D and UL 1784 compliant and the system controls are listed UL 864 for releasing devices.
Smoke Guard M3000 System - The M3000 system provides horizontal Smoke/Fire protection in ceilings typically found in atriums, non-egress stairs and light well applications. These systems are typically mounted under the floor deck can be custom made to protect openings up to 20’ wide and 30’ long and deploy upon a signal from a local smoke detection system. The units are manufactured to UL 10B, UL 10C, UL 10D, UL 864, UL1784, NFPA 252, ASTM E 84 class A standards.
Smoke Guard M4000 System - The Smoke Guard Model 4000 perimeter is a code-compliant fire-rated assembly designed to function as a vertically deploying opening protective requiring no corner posts. This perimeter curtain may be configured in a closed, box-like, condition or in a multifaceted open-ended configuration with our without side-guide captures. The curtain panel angle may vary from +/- 90° (30° - 150°) and cover up to 200 linear feet wide with a 15’ drop length. The M4000 features fire-rated pleated curtain mounted within a steel housing. The curtain assembly can be equipped with an obstruction sensor in the bottom pan to detect impediments to the deploying screen. The M4000 features a battery backup and are manufactured to UL 10B, UL 10C, UL 10D, UL 864, UL1784, NFPA 252, ASTM E 84 class A standards.
Smoke Guard Fixed Draft Curtain - SG Draft is a code-compliant, lightweight, fixed fabric curtain, semi-permanent or temporary, fire barrier system for large vertical openings. The SG Draft curtain material is a glass filament fabric with a glass fiber material on one side. SG Draft panels are manufactured in custom widths for ceiling spans of an unlimited width with a variable drop length to suit most ceiling heights. SG Draft is a cost-effective, static curtain strategy for warehouses, aircraft hangers, and manufacturing environments, used in both sprinklered and nonsprinklered buildings for automatic smoke removal.